Drager Evita 4 Ventilator – inCAV Medical And Laboratory Equipment
4.6
(784) ·
€ 2.50 ·
Auf Lager
Drager Evita 4 VentilatorCondition: Pre-owned, Calibrated, Patient Ready TECHNICAL SPECIFICATIONS Ventilation Settings Ventilation Mode:- IPPV, IPPVAssist (CMV, CMVAssist)- SIMV, SIMVASB (SIMV, SIMV/Psupp)- MMV, MMVASB (MMV, MMV/Psupp)- BIPAP1), BIPAP1)ASB, BIPAP1)Assist (PCV+, PCV+/Psupp, PCV+Assist)- APRV- CPAP, CPAP
Drager Evita 4 Ventilator
Condition: Pre-owned, Calibrated, Patient Ready
TECHNICAL SPECIFICATIONS
Ventilation Settings
- Ventilation Mode:
- IPPV, IPPVAssist (CMV, CMVAssist)
- SIMV, SIMVASB (SIMV, SIMV/Psupp)
- MMV, MMVASB (MMV, MMV/Psupp)
- BIPAP1), BIPAP1)ASB, BIPAP1)Assist (PCV+, PCV+/Psupp, PCV+Assist)
- APRV
- CPAP, CPAPASB (CPAP, CPAP/Psupp)
- ILV
- PPS (optional)
- Enhancements:
- AutoFlowTM – Automatic adaptation of inspiratory flow in volume controlled modes
- ATCTM – Automatic Tube Compensation (optional)
- NIV – Mask Ventilation (optional)
- Ventilation frequency (f): 0 to 100 /min, 0 to 150 /min (Neonatal)
- Inspiration time (Tinsp: 0.1 to 10 s
- Tidal volume (VT) (BTPS):
- 0.1 to 2.0 L (Adult)
- 0.02 to 0.3 L (Pediatric)
- 0.003 to 0.1 L (Neonatal)
- Inspiratory flow
- 6 to 120 L/min (Adult)
- 6 to 30 L/min (Pediatric and Neonatal)
- Inspiratory pressure: 0 to 80 mbar (cmH2O)
- PEEP / intermittent PEEP: 0 to 35 mbar (cmH2O)
- Pressureassist (PASB) (Psupp): 0 to 80 mbar (cmH2O)
- Rise time for inspiratory pressure: 0 to 2 s
- O2 concentration: 21 to 100 Vol.%
- Trigger sensitivity: 0.3 to 15 L/min
Measured values displayed
- Airway pressure: Peak pressure, plateau pressure, mean pressure, PEEP, min. pressure (0 to 99 mbar/cmH2O)
- Minute volume (MV), (BTPS): MV, MVspont, MVleak (0 to 99 L/min)
- Tidal volume (VT), (BTPS): Inspired VT, expired VT, VTPS (0 to 3999 mL)
- Breathing frequency (f): ftotal, fspon, fmand. (0 to150/bpm)
- O2 concentration (FiO2): Inspired O2 concentration (15 to 100 Vol.%)
- Lung mechanics
- Resistance ((0.0 to 600 mbar/L/s) (cmH2O/L/s)
- Compliance ((0.0 to 300 mL/mbar) (mL/cmH2O)
- Breathing gas temperature: 18° to 51°C
- Waveforms: Airway pressure-time, flow-time, volume-time,
- Trends (8 anyone configurable): FiO2, MV, VT, f, PEEPi, R, C, etCO2,
- Loops: Paw-V, V-Flow, Flow-Paw,
- Capnography (etCO2) (optional): 0 to 100 mmHg
- CO2 production (VCO2): 0 to 999 mL/min, STPD*
- Serial dead space Vds: 0 to 999 mL, BTPS*
- Dead space ventilation (Vds/VT): 0 to 99 %
- O2 saturation: SpO2, pulse
Alarms / Monitoring
- Airway pressure: High / Low
- Expired minute volume: High / Low
- Tidal volume: High
- Apnea alarm time: 5 to 60 s
- Spontaneous breath frequency: High
- Inspired O2 concentration: High / Low
- Breathing gas temperature: High
- SpO2 pulse (optional): High / Low
- etCO2 (optional): High / Low
Performance data
Max. flow for pressure support and spontaneous breathing: 180 L/min (adult), 60 L/min (pediatric)
Valve response time: T090 ≤ 5 ms
Control principle: Time cycled, volume constant, pressure-controlled
Safety relief valve: 100 mbar (cmH2O)
Leakage compensation
Hose system compensation
Outlet for pneumatic nebulizer
Operating data
- Mains power connection: 110 to 240 V, 50/60 Hz, 10 to 30 V DC (optional)
- Power consumption: Approx. 125 W
- Gas supply operating pressure: O2, air: 2.7 to 6 bar / 39 to 87 PSI
Physical Specifications
- Dimensions ventilator (without trolley): 530W x 290H x 450D cm (20.9 x 11.4 x 17.7 inches)
- Weight basic unit Approx. 29 kg (64 lbs.)
Machine outputs
- Digital output: Output and reception via an RS 232 C interface
- Digital output: Output for independant lung ventilation (ILV)
- Digital output: (optional) For output and reception via two RS 232 C interfaces
- Analog output (optional): For analog output of two measured values
Drager Evita 4 VentilatorCondition: Pre-owned, Calibrated, Patient Ready
TECHNICAL SPECIFICATIONS
Ventilation Settings
Ventilation Mode:- IPPV, IPPVAssist (CMV, CMVAssist)- SIMV, SIMVASB (SIMV, SIMV/Psupp)- MMV, MMVASB (MMV, MMV/Psupp)- BIPAP1), BIPAP1)ASB, BIPAP1)Assist (PCV+, PCV+/Psupp, PCV+Assist)- APRV- CPAP, CPAPASB (CPAP, CPAP/Psupp)- ILV- PPS (optional)
Enhancements:- AutoFlowTM – Automatic adaptation of inspiratory flow in volume controlled modes- ATCTM – Automatic Tube Compensation (optional)- NIV – Mask Ventilation (optional)
Ventilation frequency (f): 0 to 100 /min, 0 to 150 /min (Neonatal)
Inspiration time (Tinsp: 0.1 to 10 s
Tidal volume (VT) (BTPS):- 0.1 to 2.0 L (Adult)- 0.02 to 0.3 L (Pediatric)- 0.003 to 0.1 L (Neonatal)
Inspiratory flow- 6 to 120 L/min (Adult)- 6 to 30 L/min (Pediatric and Neonatal)
Inspiratory pressure: 0 to 80 mbar (cmH2O)
PEEP / intermittent PEEP: 0 to 35 mbar (cmH2O)
Pressureassist (PASB) (Psupp): 0 to 80 mbar (cmH2O)
Rise time for inspiratory pressure: 0 to 2 s
O2 concentration: 21 to 100 Vol.%
Trigger sensitivity: 0.3 to 15 L/min
Measured values displayed
Airway pressure: Peak pressure, plateau pressure, mean pressure, PEEP, min. pressure (0 to 99 mbar/cmH2O)
Minute volume (MV), (BTPS): MV, MVspont, MVleak (0 to 99 L/min)
Tidal volume (VT), (BTPS): Inspired VT, expired VT, VTPS (0 to 3999 mL)
Breathing frequency (f): ftotal, fspon, fmand. (0 to150/bpm)
O2 concentration (FiO2): Inspired O2 concentration (15 to 100 Vol.%)
Lung mechanics- Resistance ((0.0 to 600 mbar/L/s) (cmH2O/L/s)- Compliance ((0.0 to 300 mL/mbar) (mL/cmH2O)
Breathing gas temperature: 18° to 51°C
Waveforms: Airway pressure-time, flow-time, volume-time,
Trends (8 anyone configurable): FiO2, MV, VT, f, PEEPi, R, C, etCO2,
Loops: Paw-V, V-Flow, Flow-Paw,
Capnography (etCO2) (optional): 0 to 100 mmHg
CO2 production (VCO2): 0 to 999 mL/min, STPD*
Serial dead space Vds: 0 to 999 mL, BTPS*
Dead space ventilation (Vds/VT): 0 to 99 %
O2 saturation: SpO2, pulse
Alarms / Monitoring
Airway pressure: High / Low
Expired minute volume: High / Low
Tidal volume: High
Apnea alarm time: 5 to 60 s
Spontaneous breath frequency: High
Inspired O2 concentration: High / Low
Breathing gas temperature: High
SpO2 pulse (optional): High / Low
etCO2 (optional): High / Low
Performance data
Max. flow for pressure support and spontaneous breathing: 180 L/min (adult), 60 L/min (pediatric)
Valve response time: T090 ≤ 5 ms
Control principle: Time cycled, volume constant, pressure-controlled
Safety relief valve: 100 mbar (cmH2O)
Leakage compensation
Hose system compensation
Outlet for pneumatic nebulizer
Operating data
Mains power connection: 110 to 240 V, 50/60 Hz, 10 to 30 V DC (optional)
Power consumption: Approx. 125 W
Gas supply operating pressure: O2, air: 2.7 to 6 bar / 39 to 87 PSI
Physical Specifications
Dimensions ventilator (without trolley): 530W x 290H x 450D cm (20.9 x 11.4 x 17.7 inches)
Weight basic unit Approx. 29 kg (64 lbs.)
Machine outputs
Digital output: Output and reception via an RS 232 C interface
Digital output: Output for independant lung ventilation (ILV)
Digital output: (optional) For output and reception via two RS 232 C interfaces
Analog output (optional): For analog output of two measured values
Danisik Medical
drager – inCAV Medical And Laboratory Equipment
Drager Evita 4 Ventilator – inCAV Medical And Laboratory Equipment
Used DRAEGER Evita 4 edition Ventilator For Sale - DOTmed Listing #4445766
Ventilators – inCAV Medical And Laboratory Equipment
The Drager Evita 4 Ventilator is for every patient population. The Drager Evita 4 Ventilator was designed to meet the demanding requirements of
Drager Evita 4 Ventilator
Drager Evita 4 Ventilator – inCAV Medical And Laboratory Equipment
Drager Evita 4 Ventilator – inCAV Medical And Laboratory Equipment
DRAGER EVITA 4 VENTILATOR % (279722)